Blood Tube Colours: Which Bottle Is Used for Which Test
Blood tube colours tell staff which additive is inside, and the additive determines which tests the sample can be used for. In the UK the common ones are purple (EDTA) for a full blood count, gold or red (serum) for most chemistry and hormones, green (lithium heparin) for many urgent chemistry tests, light blue (sodium citrate) for clotting, and grey (fluoride oxalate) for glucose. The colours must be filled in a set order of draw, because additive carried from one tube into the next can corrupt a result.
Why blood tubes are colour coded
Blood behaves differently depending on what you add to it. Some tests need whole blood kept liquid; some need the blood to clot so that clear serum can be separated; some need a specific chemical to protect a fragile analyte. Each tube contains a particular additive to achieve this, and the cap is colour coded so that phlebotomy and laboratory staff can tell at a glance what is inside and which tests it suits. Put blood in the wrong colour and you have not just the wrong label — you have the wrong chemistry, and often an unusable or misleading result.
One important caveat before the details: colour conventions differ between countries and manufacturers. The colours below follow common UK practice. The US system overlaps but is not identical — for example, a serum tube may be red or gold in both, but shades and some additives vary by brand, and the US "tiger top" is a gold or red-grey speckled serum tube. Some UK labs also use a pink EDTA tube specifically for the blood bank, distinct from the purple EDTA tube used for a full blood count, precisely so the two are never confused. Always trust the tube's printed label and your local guidance over the colour alone.
Every tube colour and its additive
Purple / lavender — EDTA
Contains EDTA, an anticoagulant that works by binding calcium so the blood cannot clot, preserving the blood cells intact. This is the tube for anything that counts or examines cells. EDTA is also used for HbA1c and blood group and antibody testing.
Gold or red — serum (SST)
The gold-top serum separator tube (SST) contains a clot activator and a gel that separates on spinning; a plain red tube contains no additive and simply lets the blood clot. Both yield serum, the straw-coloured fluid left after clotting, used for the bulk of chemistry, hormones and serology.
Green — lithium heparin
Heparin is an anticoagulant that yields plasma quickly, which suits many chemistry tests, especially when a fast turnaround is needed. Because the sample does not need time to clot, it can be spun and analysed sooner than serum.
Light blue — sodium citrate
Citrate is an anticoagulant used specifically for coagulation testing (PT/INR, APTT). The tube has a precise blood-to-additive ratio (typically 9:1), which is why a blue tube must be filled exactly to the line — under-filling changes the ratio and invalidates the clotting result.
Grey — fluoride oxalate
Fluoride stops the blood cells from consuming glucose after the sample is taken (glycolysis), preserving an accurate glucose level; oxalate is the anticoagulant. Used for glucose and for lactate.
Less common tubes
You may occasionally see others. A royal blue tube is used for trace elements and toxicology, because it is made to be free of the metals that ordinary tubes can leach. A black tube (citrate at a different ratio) is used in some labs for the ESR. A yellow ACD tube is used for certain specialised tests such as tissue typing. And blood culture bottles — for detecting bloodstream infection — come as a pair, one for aerobic and one for anaerobic organisms, and are always filled first.
The colour is a signal, not a guarantee
Cap colours are not internationally standardised. A tube's printed additive is the definitive information; the colour is a fast visual cue that assumes you know your local system. When in doubt — especially comparing UK and US sources — read the label, not the lid.
Which tests go in which tube
| Cap colour | Additive | Common tests |
|---|---|---|
| Purple / lavender | EDTA | Full blood count (FBC), HbA1c, ESR, blood group & antibodies, reticulocytes |
| Gold / red | Clot activator + gel (serum) | U&E, liver function, lipids, thyroid, hormones, CRP, serology, tumour markers |
| Green | Lithium heparin | Many urgent chemistry tests, ammonia, some drug levels |
| Light blue | Sodium citrate | Coagulation — PT/INR, APTT, fibrinogen, D-dimer |
| Grey | Fluoride oxalate | Glucose, lactate |
| Pink | EDTA (blood bank) | Group & save, crossmatch (in many UK labs) |
A full blood count — often called an FBE or FBC — always goes in the purple EDTA tube, because EDTA preserves the cells so they can be counted and examined.
The correct order of draw
When several tubes are filled from one needle, they must be filled in a specific sequence. The reason is additive carryover: a trace of additive from one tube can be carried on the needle into the next, and some additives badly distort other tests (a little EDTA carried into a chemistry tube, for example, falsely lowers calcium and raises potassium). The standard order, following blood culture bottles if taken, is:
- Blood cultures (sterile) first
- Light blue — sodium citrate (coagulation)
- Gold / red — serum
- Green — heparin
- Purple — EDTA
- Grey — fluoride oxalate last
Citrate goes early to protect the sensitive clotting ratio, and EDTA and fluoride go late because their additives are the most damaging if carried into earlier tubes. Following the order is a core part of good phlebotomy technique.
Filling and mixing the tube correctly
Getting blood into the right tube is only half the job — how it is filled matters too. Tubes with an additive must be gently inverted several times immediately after filling so the blood mixes with the additive. Too little mixing lets an anticoagulant tube clot (ruining a full blood count or a clotting test); too vigorous shaking ruptures red cells and causes haemolysis. Fill volume matters as well: the light blue citrate tube in particular must reach its fill line, because the fixed blood-to-citrate ratio is what makes the clotting result valid. Vacuum tubes are designed to draw a set volume, so letting the tube fill fully before removing it is part of getting an accurate result. Smaller paediatric tubes exist for children and difficult draws, using the same colour code but a lower volume.
What happens if the wrong tube is used
Using the wrong tube — or the right tubes in the wrong order — produces results that can be flatly wrong rather than merely missing. Classic examples:
- EDTA contamination of a chemistry sample — falsely high potassium and falsely low calcium, because EDTA binds calcium and the additive salt contains potassium. This can mimic a medical emergency that does not exist.
- A clotting sample in the wrong tube — no valid result at all, because coagulation testing needs the exact citrate ratio.
- Glucose in a non-fluoride tube left standing — a falsely low glucose, because the cells keep consuming sugar in the tube.
Because a wrong-tube result can look plausible, the safeguard is prevention: correct tube, correct order, correct fill.
Sample rejection and repeat tests
Sometimes the lab cannot use a sample at all and asks for a repeat. The commonest reasons are not the patient's fault and simply reflect the biology of the sample:
- Haemolysis — red cells rupturing (from a difficult draw, a fine needle, or shaking the tube) release potassium and haemoglobin into the sample, making several results unreliable. Haemolysed samples are a leading cause of rejection.
- Clotting in an anticoagulant tube — if an EDTA or citrate tube is not mixed promptly, the blood clots and the count or clotting test cannot be done.
- Under-filling — especially a blue citrate tube not filled to the line.
- Insufficient sample or a mislabelled tube.
A rejected sample means another draw, which is frustrating but protects you from a wrong result. If your arm is sore or bruised afterwards, our guides on bruising after a blood test and whether a blood test hurts explain what is normal. To make sense of the numbers once they come back, see how to read blood test results, and browse more practical walkthroughs in our guides hub.
Sources
- Laboratory Tube Collection — StatPearls (NCBI Bookshelf)
- Phlebotomy Tubes and Order of Draw — University of Iowa Health Care, Pathology Laboratory Services Handbook
Links open official health information pages. Reference ranges and advice can differ between laboratories and countries; always follow the ranges on your own report.
Frequently asked questions
What colour bottle is used for a full blood count?
The purple (lavender) EDTA tube. EDTA stops the blood clotting and preserves the cells so they can be counted and examined, which is exactly what a full blood count needs.
What is the purple top tube for?
The purple EDTA tube is used for tests on whole blood and cells — a full blood count, HbA1c, ESR, and blood grouping and antibody testing.
What is EDTA used for?
EDTA is an anticoagulant that works by binding calcium so blood cannot clot, keeping the blood cells intact. It is the additive in the purple tube used for the full blood count and related cell tests.
What is the correct order of draw?
Blood cultures first, then light blue (citrate), gold/red (serum), green (heparin), purple (EDTA), and grey (fluoride) last. The order prevents additive from one tube contaminating the next.
What happens if blood goes in the wrong tube?
The result can be wrong rather than just missing. EDTA carried into a chemistry sample, for example, falsely raises potassium and lowers calcium, and a clotting sample in the wrong tube gives no valid result at all.